Obtain...
...an adequate sampling from the cervix using a broom-like device. Insert the central bristles of the broom into the endocervical canal deep
enough to allow the shorter bristles to fully contact the ectocervix. Push gently, and rotate the broom in a clockwise direction five times.
Rinse...
...the broom as quickly as possible into the PreservCyt® solution vial by pushing the broom into the bottom of the vial 10 times, forcing the
bristles apart. As a final step, swirl the broom vigorously to further release material. Discard the collection device.
Tighten...
...the cap so that the torque line on the cap passes the torque line on the vial.
Record...
...the patient's name and ID number on the vial. The patient information and medical history on the cytology requisition form.
Place...
...the vial and requisition in a specimen bag for transport to the laboratory.